Pick the brand on your inverter or battery label. Each code page shows what the manufacturer's manual says it means, what you can safely check, and when to call your installer or the warranty line. WattMate is not affiliated with any of these manufacturers.
Two fault families are safety faults. An insulation fault (often shown as ISO or RCD) means the inverter has found a leak to earth on the panel side, from damaged wiring, water in a junction box or a cracked panel. An arc-fault (AFCI) trip means it has detected arcing on the panel wiring, which can start a fire in the roof space. For either one, turn the system off at the DC isolator beside the inverter (the switch you can reach from the ground), stay off the roof, and call your installer or a licensed electrician. Don't reset it until someone has found the cause.
Most other codes are less urgent. A grid fault means the inverter disconnected because the grid's voltage or frequency moved outside its limits, which is the inverter doing its job; if it trips several times a week with no outage, that's a network question for Western Power. Over-temperature warnings on hot afternoons usually come down to where the inverter is mounted. A one-off high DC voltage warning on a cold, clear morning is normal, but a repeat in mild weather points to the panel wiring and is one for your installer.