As documented for Asw H T2 T3
- Meaning
- PV over voltage fault
- Likely cause
- Voltage from the PV array exceeds maximum input voltage
- What the manual says to do
- Make sure to check the open-circuit voltage of the strings and ensure it is below the maximum DC input voltage.
- Manufacturer's severity
- Critical
Solplanet's documentation says this one needs your installer.
Extracted from Solplanet's published manual. Check it against the manual for your model. Open the source document
As documented for Asw S A
- Meaning
- Grounding Connection Fault
- Likely cause
- Grounding connection may be unreliable or broken.
- What the manual says to do
- Ensure the grounding connection of the inverter is reliable. Make a visual inspection of all PV cables and modules. If this fault is still shown, contact service.
- Manufacturer's severity
- Critical
Solplanet's documentation says this one needs your installer.
Extracted from Solplanet's published manual. Check it against the manual for your model. Open the source document
As documented for Asw Sh
- Meaning
- Grounding Connection Issue
- Likely cause
- Grounding connection of the inverter is not reliable.
- What the manual says to do
- Ensure reliable grounding connection and visually inspect all cables.
- Manufacturer's severity
- Critical
Solplanet's documentation says this one needs your installer.
Extracted from Solplanet's published manual. Check it against the manual for your model. Open the source document
As documented for Asw H T2 T3 O
- Meaning
- Bus Over Voltage
- Likely cause
- Input voltage has exceeded the allowable limit.
- What the manual says to do
- Check grid voltage, consult service if issue continues.
- Manufacturer's severity
- Warning
Solplanet's documentation says this one needs your installer.
Extracted from Solplanet's published manual. Check it against the manual for your model. Open the source document
As documented for Asw45 60k Lt G3
- Meaning
- GFCI fault
- Likely cause
- Ensure the grounding connection of the inverter is reliable. Conduct a visual inspection of all PV cables and modules.
- What the manual says to do
- Check grounding and inspect PV cables for any visible damage.
- Manufacturer's severity
- Warning
Solplanet's documentation says this one needs your installer.
Extracted from Solplanet's published manual. Check it against the manual for your model. Open the source document
As documented for Asw H S2
- Meaning
- Grounding Fault
- Likely cause
- The grounding connection of the inverter may be unreliable.
- What the manual says to do
- Ensure the inverter's grounding connection is secure. If the issue persists, contact service.
- Manufacturer's severity
- Information
Solplanet's documentation says this one needs your installer.
Extracted from Solplanet's published manual. Check it against the manual for your model. Open the source document
When to call your installer or the warranty line
Your installer is your first warranty contact. If they've gone, the manufacturer's warranty line still covers the hardware. Don't open the inverter or battery case yourself: work inside it is for a licensed electrician.
If you see smoke, scorch marks or smell burning, switch the system off at the AC and PV isolators and call your installer. If anyone is in danger, call 000.
- Solplanet service network
- Open the manufacturer's service page