Solis Storage battery error code SCP
WattMate is not affiliated with Solis Storage. This page summarises Solis Storage's own published documentation; your installer and Solis Storage are the authority on your system. WattMate doesn't repair systems or make site visits.
What it means
- Meaning
- Energy Storage Battery Short Circuit
- Likely cause
- 1. The wiring of the energy storage battery is short-circuited. 2. The energy storage battery equipment is faulty.
- What the manual says to do
- 1. Inspect the cable routing and check whether the positive and negative cables are connected together. If any abnormality is found, correct it. 2. If the short-circuit protection remains, contact your dealer or customer service center.
- Manufacturer's severity
- Critical
Solis Storage's documentation says this one needs your installer.
Extracted from Solis Storage's published manual. Check it against the manual for your model. Open the source document
When to call your installer or the warranty line
Your installer is your first warranty contact. If they've gone, the manufacturer's warranty line still covers the hardware. Don't open the inverter or battery case yourself: work inside it is for a licensed electrician.
If you see smoke, scorch marks or smell burning, switch the system off at the AC and PV isolators and call your installer. If anyone is in danger, call 000.
We don't have a warranty line on file for Solis Storage yet. See the manufacturer contacts we do hold, or ask your installer.