As documented for STH 3K 8KTL
- Meaning
- Input voltage from PV panels too high
- Likely cause
- Too many panels in series resulting in high open-circuit voltage.
- What the manual says to do
- Reduce the number of PV panels in series.
- Manufacturer's severity
- Critical
Ningbo Sunways Technologies's documentation says this one needs your installer.
Extracted from Ningbo Sunways Technologies's published manual. Check it against the manual for your model. Open the source document
As documented for STS 3K 6KTL NS
- Meaning
- Photovoltaic input voltage is too high.
- Likely cause
- Too many PV panels connected leading to excess voltage.
- What the manual says to do
- Reduce the number of PV panels to ensure the open-circuit voltage is within limits.
- Manufacturer's severity
- Critical
Ningbo Sunways Technologies's documentation says this one needs your installer.
Extracted from Ningbo Sunways Technologies's published manual. Check it against the manual for your model. Open the source document
As documented for STS XKTL P
- Meaning
- PV input voltage exceeded maximum levels.
- Likely cause
- Too many PV panels connected causing high voltage.
- What the manual says to do
- Reduce the number of PV panels to ensure the open-circuit voltage is below the maximum allowed.
- Manufacturer's severity
- Critical
Ningbo Sunways Technologies's documentation says this one needs your installer.
Extracted from Ningbo Sunways Technologies's published manual. Check it against the manual for your model. Open the source document
As documented for STT 4 25KTL P
- Meaning
- Input voltage from the PV panels is too high.
- Likely cause
- Too many PV panels connected in series.
- What the manual says to do
- Reduce the number of PV panels to ensure voltage is within limits.
- Manufacturer's severity
- Critical
Ningbo Sunways Technologies's documentation says this one needs your installer.
Extracted from Ningbo Sunways Technologies's published manual. Check it against the manual for your model. Open the source document
As documented for STH4 12kW
- Meaning
- Voltage from PV input exceeds limits.
- Likely cause
- Too many PV panels connected in string.
- What the manual says to do
- Reduce the number of PV panels to keep open-circuit voltage lower than the maximum allowed input voltage.
- Manufacturer's severity
- Warning
Extracted from Ningbo Sunways Technologies's published manual. Check it against the manual for your model. Open the source document
As documented for STS XKTL
- Meaning
- PV string voltage too high
- Likely cause
- Too many PV panels causing high voltage.
- What the manual says to do
- Reduce the number of PV panels in the string.
- Manufacturer's severity
- Warning
Extracted from Ningbo Sunways Technologies's published manual. Check it against the manual for your model. Open the source document
As documented for STT 4 25KTL
- Meaning
- PV over voltage is too high.
- Likely cause
- Input voltage is too high.
- What the manual says to do
- Reduce number of PV panels connected.
- Manufacturer's severity
- Warning
Ningbo Sunways Technologies's documentation says this one needs your installer.
Extracted from Ningbo Sunways Technologies's published manual. Check it against the manual for your model. Open the source document
When to call your installer or the warranty line
Your installer is your first warranty contact. If they've gone, the manufacturer's warranty line still covers the hardware. Don't open the inverter or battery case yourself: work inside it is for a licensed electrician.
If you see smoke, scorch marks or smell burning, switch the system off at the AC and PV isolators and call your installer. If anyone is in danger, call 000.
We don't have a warranty line on file for Ningbo Sunways Technologies yet. See the manufacturer contacts we do hold, or ask your installer.