As documented for STH 3K 8KTL
- Meaning
- Firmware related fault
- Likely cause
- Corrupted firmware or internal error.
- What the manual says to do
- Restart the inverter; if issue persists, consult installer.
- Manufacturer's severity
- Critical
Ningbo Sunways Technologies's documentation says this one needs your installer.
Extracted from Ningbo Sunways Technologies's published manual. Check it against the manual for your model. Open the source document
As documented for STT 4 25KTL
- Meaning
- Internal storage anomaly.
- Likely cause
- Could be caused by a strong external magnetic field.
- What the manual says to do
- Restart inverter, if fault recurs contact Sunways.
- Manufacturer's severity
- Critical
Ningbo Sunways Technologies's documentation says this one needs your installer.
Extracted from Ningbo Sunways Technologies's published manual. Check it against the manual for your model. Open the source document
As documented for STH4 12kW
- Meaning
- Software flash corruption fault.
- Likely cause
- Corrupted firmware.
- What the manual says to do
- Restart the inverter. If the problem continues, reach out to your installer or manufacturer.
- Manufacturer's severity
- Warning
Ningbo Sunways Technologies's documentation says this one needs your installer.
Extracted from Ningbo Sunways Technologies's published manual. Check it against the manual for your model. Open the source document
As documented for STS 3K 6KTL NS
- Meaning
- Error related to the inverter's firmware.
- Likely cause
- Potential corruption of firmware or failure to flash properly.
- What the manual says to do
- Restart the inverter.
- Manufacturer's severity
- Warning
Ningbo Sunways Technologies's documentation says this one needs your installer.
Extracted from Ningbo Sunways Technologies's published manual. Check it against the manual for your model. Open the source document
As documented for STS XKTL
- Meaning
- Flash error in the inverter
- Likely cause
- The inverter may need a restart.
- What the manual says to do
- Restart the inverter.
- Manufacturer's severity
- Warning
Ningbo Sunways Technologies's documentation says this one needs your installer.
Extracted from Ningbo Sunways Technologies's published manual. Check it against the manual for your model. Open the source document
As documented for STS XKTL P
- Meaning
- Software failure observed in flash memory.
- Likely cause
- Internal software issue.
- What the manual says to do
- Restart the inverter and consult with the manufacturer if it continues.
- Manufacturer's severity
- Warning
Ningbo Sunways Technologies's documentation says this one needs your installer.
Extracted from Ningbo Sunways Technologies's published manual. Check it against the manual for your model. Open the source document
As documented for STT 4 25KTL P
- Meaning
- Firmware error detected.
- Likely cause
- Possible issue during firmware execution.
- What the manual says to do
- Restart the inverter.
- Manufacturer's severity
- Warning
Ningbo Sunways Technologies's documentation says this one needs your installer.
Extracted from Ningbo Sunways Technologies's published manual. Check it against the manual for your model. Open the source document
When to call your installer or the warranty line
Your installer is your first warranty contact. If they've gone, the manufacturer's warranty line still covers the hardware. Don't open the inverter or battery case yourself: work inside it is for a licensed electrician.
If you see smoke, scorch marks or smell burning, switch the system off at the AC and PV isolators and call your installer. If anyone is in danger, call 000.
We don't have a warranty line on file for Ningbo Sunways Technologies yet. See the manufacturer contacts we do hold, or ask your installer.