As documented for Is Hyb 1ph, Is Inv 3ph
- Meaning
- High string input voltage
- Likely cause
- The PV array is not properly configured. Excessive PV modules are connected in series to the PV string, and therefore the PV string open-circuit voltage exceeds the maximum inverter operating voltage.
- What the manual says to do
- Reduce the number of PV modules connected in series to the PV string until the PV string open-circuit voltage is less than or equal to the maximum inverter operating voltage.
- Manufacturer's severity
- Critical
iStore's documentation says this one needs your installer.
Extracted from iStore's published manual. Check it against the manual for your model. Open the source document
As documented for Is Hyb 3ph
- Meaning
- High string input voltage
- Likely cause
- The PV array is not properly configured. Excessive PV modules are connected in series to the PV string, resulting in the PV string open-circuit voltage exceeding the maximum inverter operating voltage.
- What the manual says to do
- Reduce the number of PV modules connected in series to the PV string until the PV string open-circuit voltage is less than or equal to the maximum inverter operating voltage.
- Manufacturer's severity
- Critical
Extracted from iStore's published manual. Check it against the manual for your model. Open the source document
When to call your installer or the warranty line
Your installer is your first warranty contact. If they've gone, the manufacturer's warranty line still covers the hardware. Don't open the inverter or battery case yourself: work inside it is for a licensed electrician.
If you see smoke, scorch marks or smell burning, switch the system off at the AC and PV isolators and call your installer. If anyone is in danger, call 000.
- iStore warranty phone
- 1300 552 619
- iStore warranty email
- pv.info@istore.net.au
- iStore service network
- Open the manufacturer's service page