GoodWe inverter error code VAC Failure
GoodWe uses code VAC Failure in more than one product range, and it doesn't always mean the same thing. Check which range your inverter belongs to below.
WattMate is not affiliated with GoodWe. This page summarises GoodWe's own published documentation; your installer and GoodWe are the authority on your system. WattMate doesn't repair systems or make site visits.
As documented for Ehb
- Meaning
- Grid voltage is not within permissible range
- Likely cause
- Inverter detects that AC voltage is beyond the normal range required by safety country
- What the manual says to do
- Check (use multi-meter) if the AC voltage (Between L & N) is within a normal range, and ensure AC cables are connected tightly.
- Manufacturer's severity
- Critical
GoodWe's documentation says this one needs your installer.
Extracted from GoodWe's published manual. Check it against the manual for your model. Open the source document
As documented for Et
- Meaning
- Grid voltage is not within permissible range
- Likely cause
- Inverter detects that AC voltage is beyond the normal range required by the safety country
- What the manual says to do
- 1. Make sure safety country of the inverter is set right. 2. Check (use multi-meter) if the AC voltage (Between L&N) is within a normal range (also on AC breaker side) 3. Make sure the grid voltage of your area is stable and within normal range.
- Manufacturer's severity
- Critical
GoodWe's documentation says this one needs your installer.
Extracted from GoodWe's published manual. Check it against the manual for your model. Open the source document
As documented for Gep5 10kw
- Meaning
- Voltage AC failure.
- Likely cause
- Grid is not connected.
- What the manual says to do
- Check grid cable connection and ensure the grid is available.
- Manufacturer's severity
- Warning
GoodWe's documentation says this one needs your installer.
Extracted from GoodWe's published manual. Check it against the manual for your model. Open the source document
As documented for Gt
- Meaning
- Grid voltage out of range
- Likely cause
- The utility grid voltage is out of the allowed range.
- What the manual says to do
- The manual's steps for this code are for your installer.
- Manufacturer's severity
- Warning
GoodWe's documentation says this one needs your installer.
Extracted from GoodWe's published manual. Check it against the manual for your model. Open the source document
As documented for Geh
- Meaning
- Grid voltage is not within permissible range
- Likely cause
- Inverter detects that AC voltage is beyond the normal range required by the safety country
- What the manual says to do
- Make sure safety country of the inverter is set right. Check (use multi-meter) if the AC voltage (Between L & N) is within a normal range (also on AC breaker side).
- Manufacturer's severity
- Warning
Extracted from GoodWe's published manual. Check it against the manual for your model. Open the source document
When to call your installer or the warranty line
Your installer is your first warranty contact. If they've gone, the manufacturer's warranty line still covers the hardware. Don't open the inverter or battery case yourself: work inside it is for a licensed electrician.
If you see smoke, scorch marks or smell burning, switch the system off at the AC and PV isolators and call your installer. If anyone is in danger, call 000.