Deye error code F58
Deye uses code F58 in more than one product range, and it doesn't always mean the same thing. Check which range your equipment belongs to below.
WattMate is not affiliated with Deye. This page summarises Deye's own published documentation; your installer and Deye are the authority on your system. WattMate doesn't repair systems or make site visits.
As documented for Single Phase Hybrid Inverter
- Meaning
- BMS communication fault
- Likely cause
- 1. it tells the communication between hybrid inverter and battery BMS disconnected when 'BMS_Err-Stop' is active; 2. If don't want to see this happen, you can disable 'BMS_Err-Stop' item on the LCD; 3. If the fault still exists, please contact us for help.
- What the manual says to do
- Follow the troubleshooting steps.
- Manufacturer's severity
- Critical
Deye's documentation says this one needs your installer.
Extracted from Deye's published manual. Check it against the manual for your model. Open the source document
As documented for Ai W
- Meaning
- BMS communication fault
- Likely cause
- Communication lost between inverter and battery BMS.
- What the manual says to do
- Disable BMS Err-Stop on the LCD; contact support if issues persist.
- Manufacturer's severity
- Warning
Deye's documentation says this one needs your installer.
Extracted from Deye's published manual. Check it against the manual for your model. Open the source document
As documented for N A
- Meaning
- BMS communication fault
- Likely cause
- Disconnection between inverter and battery BMS.
- What the manual says to do
- Check BMS connection; you may disable BMS error reporting if unwanted.
- Manufacturer's severity
- Warning
Extracted from Deye's published manual. Check it against the manual for your model. Open the source document
As documented for Grid Connected Pv Inverter
- Meaning
- AC grid U over current
- Likely cause
- Hardly appear the code. Never ever happened so far.
- What the manual says to do
- Monitor for reoccurrence.
- Manufacturer's severity
- Information
Extracted from Deye's published manual. Check it against the manual for your model. Open the source document
When to call your installer or the warranty line
Your installer is your first warranty contact. If they've gone, the manufacturer's warranty line still covers the hardware. Don't open the inverter or battery case yourself: work inside it is for a licensed electrician.
If you see smoke, scorch marks or smell burning, switch the system off at the AC and PV isolators and call your installer. If anyone is in danger, call 000.
- Deye warranty phone
- (02) 8529 6809
- Deye warranty email
- service_au@deye.com.cn
- Deye service network
- Open the manufacturer's service page