As documented for Grid Connected Pv Inverter
- Meaning
- AC lower frequency
- Likely cause
- Check the frequency protection setting.
- What the manual says to do
- Adjust frequency settings as needed.
- Manufacturer's severity
- Critical
Deye's documentation says this one needs your installer.
Extracted from Deye's published manual. Check it against the manual for your model. Open the source document
As documented for Ai W
- Meaning
- AC lower frequency
- Likely cause
- Grid frequency below specification.
- What the manual says to do
- Verify grid frequency; reach out for support if the problem continues.
- Manufacturer's severity
- Warning
Deye's documentation says this one needs your installer.
Extracted from Deye's published manual. Check it against the manual for your model. Open the source document
As documented for N A
- Meaning
- AC lower frequency
- Likely cause
- Grid frequency below normal range.
- What the manual says to do
- Ensure cables are intact; contact support if not resolved.
- Manufacturer's severity
- Warning
Deye's documentation says this one needs your installer.
Extracted from Deye's published manual. Check it against the manual for your model. Open the source document
As documented for Single Phase Hybrid Inverter
- Meaning
- AC lower frequency
- Likely cause
- Grid frequency out of range
- What the manual says to do
- 1. Check the frequency is in the range of specification or not; 2. Check whether AC cables are firmly and correctly connected; 3. Seek help from us, if cannot go back to normal state.
- Manufacturer's severity
- Warning
Deye's documentation says this one needs your installer.
Extracted from Deye's published manual. Check it against the manual for your model. Open the source document
When to call your installer or the warranty line
Your installer is your first warranty contact. If they've gone, the manufacturer's warranty line still covers the hardware. Don't open the inverter or battery case yourself: work inside it is for a licensed electrician.
If you see smoke, scorch marks or smell burning, switch the system off at the AC and PV isolators and call your installer. If anyone is in danger, call 000.
- Deye warranty phone
- (02) 8529 6809
- Deye warranty email
- service_au@deye.com.cn
- Deye service network
- Open the manufacturer's service page