Alpha ESS error code 110006
Alpha ESS uses code 110006 in more than one product range, and it doesn't always mean the same thing. Check which range your equipment belongs to below.
WattMate is not affiliated with Alpha ESS. This page summarises Alpha ESS's own published documentation; your installer and Alpha ESS are the authority on your system. WattMate doesn't repair systems or make site visits.
As documented for Smile B5 Series
- Meaning
- Over Temperature Alarm
- Likely cause
- Poor ventilation or direct sunlight exposure.
- What the manual says to do
- Check installation conditions and contact service if necessary.
- Manufacturer's severity
- Critical
Alpha ESS's documentation says this one needs your installer.
Extracted from Alpha ESS's published manual. Check it against the manual for your model. Open the source document
As documented for Smile
- Meaning
- over_temperature_alarm
- Likely cause
- Installation site exposure or poor ventilation.
- What the manual says to do
- Check ambient conditions and contact customer service.
- Manufacturer's severity
- Warning
Alpha ESS's documentation says this one needs your installer.
Extracted from Alpha ESS's published manual. Check it against the manual for your model. Open the source document
As documented for Smile M5
- Meaning
- Over Temperature Alarm
- Likely cause
- Humidity or exposure to high temperature.
- What the manual says to do
- Ensure ventilation; check ambient conditions.
- Manufacturer's severity
- Warning
Alpha ESS's documentation says this one needs your installer.
Extracted from Alpha ESS's published manual. Check it against the manual for your model. Open the source document
As documented for Stax
- Meaning
- Over temperature alarm
- Likely cause
- Inspect installation site for adequate ventilation and temperature management.
- What the manual says to do
- Contact service contact if thermal issues become recurrent.
- Manufacturer's severity
- Warning
Alpha ESS's documentation says this one needs your installer.
Extracted from Alpha ESS's published manual. Check it against the manual for your model. Open the source document
As documented for Smile Bat
- Meaning
- over_temperature_alarm
- Likely cause
- Please verify whether installation subject to sunlight or heating.
- What the manual says to do
- Contact support for persistent alarm.
- Manufacturer's severity
- Warning
Alpha ESS's documentation says this one needs your installer.
Extracted from Alpha ESS's published manual. Check it against the manual for your model. Open the source document
As documented for Smile Bat 13 3p
- Meaning
- Over Temperature Alarm
- Likely cause
- High ambient temperature or insufficient ventilation
- What the manual says to do
- Ensure proper ventilation; contact customer service if frequent
- Manufacturer's severity
- Warning
Alpha ESS's documentation says this one needs your installer.
Extracted from Alpha ESS's published manual. Check it against the manual for your model. Open the source document
When to call your installer or the warranty line
Your installer is your first warranty contact. If they've gone, the manufacturer's warranty line still covers the hardware. Don't open the inverter or battery case yourself: work inside it is for a licensed electrician.
If you see smoke, scorch marks or smell burning, switch the system off at the AC and PV isolators and call your installer. If anyone is in danger, call 000.
- Alpha ESS warranty phone
- +61290007676
- Alpha ESS warranty email
- techsupport@alphaess.au
- Alpha ESS service network
- Open the manufacturer's service page